Download our free SNMP White Paper. Featuring SNMP Expert Marshall DenHartog.
This guidebook has been created to give you the information you need to successfully implement SNMP-based alarm monitoring in your network.
1-800-693-0351
Have a specific question? Ask our team of expert engineers and get a specific answer!
Sign up for the next DPS Factory Training!
Whether you're new to our equipment or you've used it for years, DPS factory training is the best way to get more from your monitoring.
Reserve Your Seat TodayThe NetMediator is like an RTU on steroids - it does everything the NetGuardian 832A does, and then some. It's a full-featured alarm collector and protocol mediation device in one. You can mediate and monitor, saving you the expense of buying additional RTUs.
Protocols: SNMP, TL1, TBOS Mediation: 8 TBOS displays to SNMP or TL1 Discrete Inputs: 32 Analog Inputs: 8 (voltage/current) Analog Input Range: -70 to 94 VDC or 4 to 20 mA Control Outputs: 8 Maximum Voltage: 60 VDC/120 VAC Maximum Current: 1 Amp, AC/DC Interface:
| Visual Interface: 18 LEDs, LCD display Dimensions: 1.75"H x 17"W x 12"D (4.5 cm x 43.2 cm x 30.5 cm) Weight: 4 lbs. 3 oz. (1.9 kg) Mounting: 19" or 23" rack Power Input: +24 VDC Current Draw: 200 mA Fuse: 0.75 Amp GMT Operating Temperature: 32°-140° F (0°-60° C) Operating Humidity: 0%-95% noncondensing |
Ordinarily, if you want to get SNMP Traps from your Main Distribution Frame, you're looking at hours of work and a hefty price in technicians' time and overtime pay.
First you've got to collect all the wires at your Main Distribution Frame and tie them down to a terminal block. Then you've got to cross connect the wires from the terminal block to an SNMP RTU - and that means running the wires over an equipment ladder and sewing them down.
There's an easier way - the Remote Alarm Block 176N. It's a remote alarm block and SNMP RTU in one unit. The RAB installs right in your Main Distribution Frame. Tie all the wires to the RAB - and the only thing you've got going out is a nice, clean Ethernet cable ... straight to your LAN and your SNMP manager.
Protocols: SNMP, DCPx, DCPf, DCP, and DCP1 Discrete Point Inputs: 176 Alarm Detection Speed: Configurable to 100-10000 msec Control Outputs: Relay contacts, 2 Form A, 2 Form C Maximum Voltage: 60 VDC/120 VAC Maximum Current: 1 Amp, AC/DC Interfaces:
| Visual Display: 6 bicolor LEDs Dimensions: 4"x 8"x 5" (10.2 cm x 20.3 cm x 12.7 cm) Weight: 4 lbs (1.8 kg) Mounting: 19" rack, 23" rack, or wall mounting Power Input: -48VDC (-40 to -70 VDC) Current Draw: 50 mA Fuse: 1 Amp GMT Operating Temperature: 32° -140° F (0° - 60° C) Operating Humidity: 0%-95% noncondensing |