3127

Get a Live Demo

You need to see DPS gear in action. Get a live demo with our engineers.

Get the Alarm Fundamentals White Paper

Download our free Monitoring Fundamentals Tutorial.

An introduction to Monitoring Fundamentals strictly from the perspective of telecom network alarm management.

DPS is here to help.

1-800-693-0351

Have a specific question? Ask our team of expert engineers and get a specific answer!

Learn the Easy Way

Sign up for the next DPS Factory Training!

DPS Factory Training

Whether you're new to our equipment or you've used it for years, DPS factory training is the best way to get more from your monitoring.

Reserve Your Seat Today

Badger Replacement and Compatibility Solution

This modern remote monitoring master is compatible with your Badger remotes - and provides a smooth migration path for replacing your Badger system

Here's a solution to your Badger compatibility problem - a modern remote monitoring master that is Badger compatible. With the TMon / IAM Remote Monitoring System, you can:

  • Poll your existing Badger remotes.
  • Use advanced features like after-hours pager alarm notifications, Web browser interface, nuisance alarm filtering, and more
  • Monitor all your other systems using SNMP, TL1, and over 25 other standard, proprietary, and legacy protocols
  • Gradually replace your Badger remotes on your schedule with advanced modern remotes -
    with no forklift swapouts

Select an option below to find Badger compatibility solutions ...

Option 1: TMon / IAM remote monitoring system product details
Option 2: Sign up for a free web conference demonstration
Option 3: See details of Badger compatibility applications

Legacy Alarm Monitoring Equipment Replacement

You want to replace your Badger master, but you can't afford a forklift swapout of your Badger remotes

It's time to replace your current Badger or Larse master with something new, but you don't want to change your whole system - with good reason. You don't want to do a forklift swapout of all your Badger remotes.

You can't afford the equipment replacement and manpower costs of replacing all your Badger remotes at all your remote sites.

Badger compatibility means you don't have to replace your remotes all at once - you can replace just your master and get all the advantages of a modern, advanced system at a fraction of the cost.

Use advanced remote monitoring features with your existing Badger remotes

When you replace your current Badger master with a TMon / IAM Remote Monitoring System, you'll immediately get the benefit of advanced monitoring features:

  • After-hours alarm notifications: T/Mon / IAM supports pager and e-mail alarm notifications, giving your on-call techs full information about remote site problems, even at 3 in the morning
  • Web interface: Everybody knows how to use a web browser. A web interface makes sure all your field techs can access your alarm system, from any computer from any location.
  • Nuisance alarm filtering: TMon / IAM filters out status alerts, oscillating conditions, and unimportant alarms.
  • Integrated multiprotocol support: TMon / IAM supports over 25 protocols, including SNMP, TL1, TBOS, TABS, plus numerous proprietary protocols from Badger, Larse, NEC, and others. You can get rid of your specialized consoles and monitor your whole network from one screen.

Gradually replace your Badger remotes without forklift swapouts

Once your TMon / IAM Remote Monitoring System is in place, you have multiple options for replacing your Badger remotes without the financial shock of a forklift swapout:

  • Run both modern advanced remotes and legacy Badger remotes side-by-side.
  • Begin your replacement on your schedule, not all at once.
  • Replace your Badger remotes with new remotes as fast or as slow as your time, budget, and manpower resources allow.

It's the sensible, cost-effective way to replace your legacy Badger system.

This is the only Badger compatibility solution that is guaranteed to work for you and backed by a no-risk, money back guarantee

Bob Berry - CEO, DPS Telecom, offers guarranteed Badger compatibility

"Every remote network alarm monitoring system I make is backed by my no-risk, money-back guarantee. If you buy my equipment and you're not satisfied for any reason during the first 30 days, simply return it for a full refund. If my product doesn't solve your problem, I don't want you to have it."
- Bob Berry, CEO, DPS Telecom

Select an option below to find guaranteed, no-risk solutions for Badger compatibility ...


Option 1: TMon / IAM remote monitoring system product details
Option 2: Sign up for a free web conference demonstration
Option 3: See details of Badger compatibility applications



Mediate Badger, Larse, and NEC to SNMP

Mediate Badger, Larse, and NEC Other Legacy Gear To SNMP...
Mediate Badger, Larse, and NEC Other Legacy Gear To SNMP...
Equipment Used:

How This Application Works:

The software modules listed in the 'Equipment Used' section will allow NOC to poll multiple legs of Larse and NEC remotes in one common platform and provide the protocol mediation to SNMP. We also recommened a database conversion utility for both systems which will allow your existing database to be substantially transferred to the T/MON NOC, saving considerable time preventing errors.

The T/Mon NOC will perform many critical functions such as collecting, filtering, categorizing & presenting your alarms. T/Mon is ideal for maintaining history, alphanumeric paging and e-mail notification. One of the most powerful features of the T/Mon NOC is its ability to mediate alarms to other protocols. The SNMP responder module will provide alarm visibility at other locations that use an SNMP manager.



Poll the Badger 475 from T/Mon

Monitor Badger 475 RTUs with PSK Polling using T/Mon NOC
Monitor Badger 475 RTUs with PSK Polling using T/Mon NOC

Equipment Used:

How This Application Works:

We have proven, in our test lab, that we can poll the Badger 475 units successfully from our T/Mon Master Station using a PSK Interface. Also included in this application is the Badger Polling Software that will enable this increased functionality.

In order to interface with the PSK Polling leg, we will need to add an external device. This interface will dock with one of the T/Mon NOCs available RS232 Ports.

Additional Details about the RS232 to PSK Polling Interface:

RS232 to PSK Polling Interface,-48VDC, 19 and 23" Rack Mountable. Electrical interface adapter chassis that will Bi-directionally convert RS232 to PSK (Phase Shift Keying). 1 RU tall, rack mountable in 19 or 23 inch shelves. Connectorized. Front panel activity LED's. -48vdc power supply.



See Also: